Turgo type single nozzle Hydro Turbine 500 Watts

Model No:XJ18-0.5DCT4-Z
Output/Power:500 watt
Rated Head:12 – 18 Meters
Rated Flow:5 – 7 (l/s)

XJ18-0.5DCT4 is an AC direct systems consisting of a turbine-generator unit producing AC power which is used as needed. That is, it is fed directly to the appliances. No need for a battery and inverter, XJ18-0.5DCT4 offers a complete water-to-wire system with an integral Turgo turbine, generator and valve flow control. Designed to deliver ready-to-use 115V/230V AC power, it employs a brushless, special rare-earth permanent magnet  alternator and therefore has a higher efficiency than ordinary alternator.  Output voltage and frequency are controlled by the electronic load controller (with ballast). The power is monitored and that which is not used by the appliances is directed to the ballast,  As little as 5 to 7(26 gallon) liter per second (l/s) falling 18 meter through a pipe, it can supply enough power to comfortably run a small household. This machine is compact, easy to install, and requires little maintenance except lubricating the bearing every few months.

Water is collected upstream from the turbine and channeled in a pipe down to the turbine location. At the turbine, the water passes through a nozzle, where it accelerates, strikes the turbine runner, and turns an AC single-phase brushless permanent magnet alternator. An electric load controller is built on the alternator which stabilizes the voltage to 110V or 220V to protect electrical appliances during use. Installation is very simple and explained in the manual. Once installed there are no running costs and maintenance costs are very low.

OUTPUT IN WATTS against various head and flow
Water head
(meter)
Water flow(liter/second)
4 liter/sec
5 liter/sec
6 liter/sec
7 liter/sec
10
120W
250W
300W
385W
11
132W
275W
330W
423W
12
144W
300W
360W
462W
13
156W
325W
390W
500W
14
168W
350W
420W
500W
15
180W
375W
450W
500W
16
192W
400W
480W
500W
17
204W
425W
500W
500W
18
216W
450W
500W
500W